Steam Methane Reforming¶
This dataset contains techno-economic data on steam methane reforming (including auto-thermal reforming) with and without carbon capture for producing hydrogen.
Fields¶
The techno-economic data is distinguished across the following fields.
Subtechnologies (subtech)¶
- SMR: Steam Methane Reforming
- ATR: Autothermal Reforming
Aggregated parameters¶
All data in this dataset can be aggregated via the NOSLAG workflow, which yields the following parameters:
| Loading ITables v2.9.1 from the internet... (need help?) |
| ⓘ | variable | Lifetime | OCF | Output Capacity|Hydrogen | Output|Hydrogen | CAPEX | Capture Rate | Input|Electricity | Input|Natural Gas | OPEX Fixed | OPEX Variable | Total Output Capacity|Hydrogen | Output|Electricity |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| unit | year | percent | cubic_meter_H2_norm/hour | MWh_H2_LHV | EUR_2024 | percent | MWh | MWh_NG_LHV | EUR_2024/yr | EUR_2024 | lb_H2/hour | MWh | |
| subtech | capture_rate | ||||||||||||
| SMR | 0.00% | 27.5 | 92.5 | 1.0 | 1.0 | 2350.0 | 0.0 | 0.0194 | 1.40 | 75.2 | 1.630 | 31400.0 | 0.0355 |
| SMR | 55.70% | 27.5 | 92.5 | 1.0 | 1.0 | 3510.0 | 55.7 | 1.46 | 116.0 | 0.298 | 31400.0 | 0.00534 | |
| SMR | 90.00% | 27.5 | 92.5 | 1.0 | 1.0 | 5300.0 | 90.0 | 1.55 | 153.0 | 0.280 | 31400.0 | 0.00153 | |
| SMR | 96.20% | 27.5 | 92.5 | 1.0 | 1.0 | 4230.0 | 96.2 | 0.0611 | 1.47 | 110.0 | 8.230 | 31400.0 | |
| ATR | 94.50% | 30.0 | 90.0 | 1.0 | 1.0 | 3340.0 | 94.5 | 0.12 | 1.38 | 85.4 | 12.200 | 60600.0 |
Comparison¶
The figure below compares key parameters of the different technology options.
Raw data¶
The table below contains the raw data contained in this dataset. The raw data has not be normalised or harmonised in any way and should closely resemble the data as it is reported by the respective sources. You can also find this data in the GitHub repo in this file: posted/database/tedfs/Tech/Steam Methane Reforming.csv
| Loading ITables v2.9.1 from the internet... (need help?) |
| ⓘsource | source_detail | subtech | capture_rate | period | variable | reference_variable | value | uncertainty | unit | reference_value | reference_unit | comment |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IEA-GHG-2017 | Page 8 of 286, Section General Criteria for Economic Evaluation | SMR | * | 2017 | Lifetime | 25 | year | |||||
| IEA-GHG-2017 | Page 236 of 286, Sheet 99 of 112, Section 8.3.2 | SMR | * | 2017 | OCF | 95 | percent | |||||
| IEA-GHG-2017 | Page 13 of 286, Section Plant Performance | SMR | * | 2017 | Total Output Capacity|Hydrogen | 100000 | cubic_meter_H2_norm/hour | |||||
| IEA-GHG-2017 | Page 278 of 286, Sheet 111 of 112, Annex III, Base Case (no capture) | SMR | 0.00% | 2017 | CAPEX | Output Capacity|Hydrogen | 222886722 | EUR_2014 | 100000 | cubic_meter_H2_norm/hour | ||
| IEA-GHG-2017 | Page 16 of 286, Section Plant Performance, Table 2: Plant Performance Summary, Base Case (no capture) | SMR | 0.00% | 2017 | Capture Rate | 0 | percent | |||||
| IEA-GHG-2017 | Page 16 of 286, Section Plant Performance, Table 2: Plant Performance Summary, Base Case (no capture) | SMR | 0.00% | 2017 | Input|Natural Gas | Output|Hydrogen | 14.212 | MJ_NG_LHV | 1 | cubic_meter_H2_norm | ||
| IEA-GHG-2017 | Page 18 of 286, Section Operating Cost, Table 4: Operating Cost of SMR Based H2 Plant, Base Case (no capture) | SMR | 0.00% | 2017 | OPEX Fixed | Output Capacity|Hydrogen | 7545514 | EUR_2014/year | 100000 | cubic_meter_H2_norm/hour | ||
| IEA-GHG-2017 | Page 18 of 286, Section Operating Cost, Table 4: Operating Cost of SMR Based H2 Plant, Base Case (no capture) | SMR | 0.00% | 2017 | OPEX Variable | Output|Hydrogen | 519365 | EUR_2014 | 95000 | cubic_meter_H2_norm/hour*year | Annual production is 95 % of one year times 100,000 Nm³/h. Variable costs exclude feedstock and fuel costs. | |
| IEA-GHG-2017 | Page 16 of 286, Section Plant Performance, Table 2: Plant Performance Summary, Base Case (no capture) | SMR | 0.00% | 2017 | Output|Electricity | Output|Hydrogen | 9.918 | MWh | 100000 | cubic_meter_H2_norm | ||
| IEA-GHG-2017 | Page 278 of 286, Sheet 111 of 112, Annex III, Case 1A (CO2 Capture from Shifted Syngas using MDEA) | SMR | 55.70% | 2017 | CAPEX | Output Capacity|Hydrogen | 263906811 | EUR_2014 | 100000 | cubic_meter_H2_norm/hour | ||
| (33 more rows not shown) | ||||||||||||